Printer's Parts Store, Inc.

 

7409 NW 103 Terrace      Oklahoma City, OK  73162

 

405-721-1701     1-800-375-3787          ppsokc@aol.com  

 

SOFT STARTERS

 

 

SOFT STARTERS
Home Up DOWNLOADS NEW EQUIPMENT USED EQUIPMENT

 

 

 

 

Worldwide Electric Heavy Duty Solid State Reduced Voltage Soft Starters

Worldwide Electric Heavy Duty Non-Combination Solid State Reduced Voltage Soft Starters

worldwide electric heavy duty irrigation soft starters with motor-saver technology

solid state soft starters

solid state soft start starters advanced design crusher starters

soft starters for high-feature application

 

 

Worldwide Electric Heavy Duty Solid State Reduced Voltage Soft Starters

             

  • Multiple Ramp Types To Start Any Load - Closed Loop Current Ramp Or Voltage Ramp, With Or Without Current Limit

  • Unit Overload Capacity (% FLA) - 500% - 30 Seconds, 1.15 S.F. With Line Start Rated Bypass

  • Start & Run Protection - Two Programmable Overload Trip Curves Allow For The Thermal Capacity Required To Start The Load While Providing Motor Overload Protection Needed During Run Time

         Start: Programmable For Class 5-30

         Run: Programmable For Class 5-30, Enabled When Starter Detects Motor Is "At-Speed"

         Reset: Manual Or Automatic, Selectable Via Programming.

  • Phase Current Imbalance/Loss Protection - Trip Level: 5 - 30% Current Imbalance Between Any Two Phases With Trip Delay

  • Phase Loss - Trips On Phase Current Or Voltage Loss

  • Phase Rotation - Phase Rotation Trip Can Be Set To A-B-C, A-C-B Or Disabled

  • Electronic Shear Pin Protection - Trip Level: 100 - 300 % Of Motor FLA With Trip Delay

  • Load Loss (Under Current) Trip Protection - Trip Level: 10 - 90% Of Motor FLA With Trip Delay

  • Motor Duty Cycle Protection - Back-Spin/Coast-Down, Starts-Per-Hour Or Minimum Time Between Starts Lockouts. Restart Delay After A Power Failure. Trips At 10x Unit Current Rating During Run.

  • Shorted SCR  - Locks Out On Any Single Shorted SCR (Defeatable) Or Can Provide Shunt Trip Function If Multiple SCR's Short Or Bypass Contactor Is Welded Closed.

  • Short Circuit - Trips At 10x Unit Current Rating During Run. Checks For Shorted Load Prior To Each Start.

  • Metering - Monitors Phase Current, Ground Current And Motor Thermal Capacity

 

Worldwide Electric Heavy Duty Non-Combination Solid State

    Reduced Voltage Soft Starters

Features:

  • Motor-Saver Technology
  • Programmable Adjustable Electronic Overload
  • 120V Control Power Transformer
  • Heavy Duty Integral Bypass - Full Voltage Rated
  • White Powder Coated Finish
  • Two Pre-Punched Holes For Optional Controls
  • Available Options - Start/Stop Pushbutton, Hand-Off Auto Switch & Run Pilot Light Kit

NEMA 1/4/12 Enclosure - No Circuit Breaker

HP By Voltage

Model

Number

Max

FLA

Dimensions

(Inches)

230V

460V

10 25 WWE02534N1 40 24X16X8
20 40 WWE04034N1 55 24X16X8
25 50 WWE05034N1 68 24X16X8
40 75 WWE07534N1 125 36X24X8
50 100 WWE10034N1 156 48X24X12
75 150 WWE15034N1 220 48X24X12
100 200 WWE20034N1 248 48X24X12
150 300 WWE30034N1 400 60X24X12
200 400 WWE40034N1 480 60X24X12

 

 

worldwide electric heavy duty irrigation soft starters with

    motor-saver technology

applications:

  • water treatment systems

  • waste water treatment plans

  • oil field pumping sytems

  • irrigation pumps

features:

  • 460V - three-phase - 60 Hz

  • NEMA 4/12 enclosure

  • Built-in Circuit Breaker With Door-Mounted Lockable Operator Handle

  • Heavy Duty Integral Bypass - Full Voltage Rated

  • 120 Volt Control Power Transformer

  • Programmable Adjustable Electronic Overload

  • Overload Rated 500 % For 30 Seconds

  • Advanced Motor Protection

  • Suitable For Use As Service Equipment

  • Interface Board For Easy Control Connections

  • Door Mounted Keypad & Pilot Devices

  • Smart Door - Includes:

    • Digital Keypad

    • Start / Stop Pushbutton

    • Hand / Off / Auto Selector Switch

    • Motor Run Pilot Light

    • Power On Pilot Light

    • Field Trip Reset

  • With Five (5) External / Fault Indicators With Amber Lights

  • Pump Ramp Down Feature

  • Double Redundant LED Pilot Lights

  • UL Listed / CE Certified / C-UL Listed

 

 

HP By Voltage

Model

Number

Max

FLA

Dimensions

(Inches)

230V

460V

25 50 WWEPPSSRV12-50 68 37x15x12
40 75 WWEPPSSRV12-75 125 37x15x12
50 100 WWEPPSSRV12-100 156 48x33x16
60 125 WWEPPSSRV12-125 156 48x33x16
75 150 WWEPPSSRV12-150 220 48x33x16
100 200 WWEPPSSRV12-200 248 48x33x16
150 300 WWEPPSSRV12-300 400 48x33x16

 

worldwide electric advanced crusher design heavy duty reduced

    voltage soft starters with motor-saver technology

application:

  • crushers

  • pumps

  • fans

  • compressors

  • pulverizers

  • shredders

  • mills / saws

  • conveying systems and lifts

 

 

    

Features:

  • NEMA 4/12 enclosure

  • built in circuit breaker (30-600HP) or fusible disconnect (25HP) with door-mounted lockable operator handle

  • heavy duty integral bypass - full voltage rated

  • 120 volt control power transformer

  • programmable adjustable electronic overload

  • Overload Rated 500 % For 30 Seconds

  • Advanced Motor Protection

  • Suitable For Use As Service Equipment

  • Interface Board For Easy Control Connections

  • Door Mounted Keypad & Pilot Devices

  • Smart Door - Includes:

    • Digital Keypad

    • Start / Stop Pushbutton

    • Local / Off / Remote Selector Switch

    • Emergency Stop Pushbutton

    • Motor Run Pilot Light

    • Power On Pilot Light

    • Start Fault Pilot Light

    • E-Stop Fault Pilot Light

    • External Interlock Pilot Light

  • Double Redundant LED Pilot Lights

  • UL Listed / CE Certified / C-UL Listed

 

HP By Voltage

Model

Number

Max

FLA

Dimensions

(Inches)

230V

460V

15 25 WWEACDSSRV-25 40 37x15x12
15 30 WWEACDSSRV-30 45 37x15x12
20 40 WWEACDSSRV-40 55 37x15x12
25 50 WWEACDSSRV-50 68 37x15x12
30 60 WWEACDSSRV-60 96 37x15x12
40 75 WWEACDSSRV-75 125 37x15x12
50 100 WWEACDSSRV-100 156 48x33x16
60 125 WWEACDSSRV-125 156 48x33x16
75 150 WWEACDSSRV-150 220 48x33x16
100 200 WWEACDSSRV-200 248 48x33x16
125 250 WWEACDSSRV-250 400 48x33x16
150 300 WWEACDSSRV-300 400 48x33x16
20 400 WWEACDSSRV-400 480 48x33x16
250 500 WWEACDSSRV-500 600 48x33x16
300 600 WWEACDSSRV-600 800 92x36x30

 

solid state soft starters

  • All Units Include 115 Volt Control Power Transformer

  • All Units Include ESP100 Solid State Overload

  • All Units Made For Heavy Duty, High Torque Applications

  • All Units Fan Cooled

  • All Units Have Adjustable Start Times and Torque Settings

  • All Units UL Listed and CSA Certified

Advantages:

These Controls Offer An Affordable Solution For Your Motor Control Needs. Our Soft Start Controllers and Starters Incorporate The Latest In Solid-State Technology Providing Precise Control Of The Starting and Stopping Of Any AC Induction Motor. Solid-State Reduced Voltage Starting Allows Motor Voltage To Be Gradually Applied, Reducing Potentially Damaging High Inrush Currents and Starting Torques.

 

Smooth Start and Stop:

AC Induction Motors and Their Associated High Torque Starting Have Been A Routine Cause Of Problems For Plant and Maintenance Engineers. You Can Put An End To Those 230 Volt Problems With High Quality, Solid-State Motor Controls. They Apply Start and Stopping Power Smoothly Over A Wide Range Of Applications.

 

Superior Performance:

Since 1979, This Manufacturer Has Specialized In The Development Of Rugged and Reliable Industrial Solid-State Motor Controls. 460 Volt These Solid-State Motor Controllers and Starters Have Long Been Recognized For Their Superior Technical and Performance Standards.

 

Wide Range:

We Offer One Of The Widest Ranges Of Solid-State Motor Control Products In

The Industry For Both Retrofit and OEM Applications.

 

 

NEMA 1 Enclosure 

No Circuit Breaker

Max

HP

Model

Number

230 Volt
25 SK3N1025N
40 SM3N1040N
50 SN3N1050N
75 SQ3N105N
100 SR3N1100N
150 ST3N1150N
200 SW3N1200N
300 SY3N1300N
460 Volt
40 SJN1040N
50 SK4N1050N
75 SM4N1075N
100 SN4N1100N
150 SQ4N1150N
200 SR4N1200N
300 ST4N1300N
400 SW4N1400N
600 SY4N1600N

 

solid state soft start starters

advanced design crusher starters

 

Applications:

  • Crushers

  • Pulverizers

  • Shredders

  • Wood Hogs

  • Pellet Mills

Features:

  • NEMA 4 Enclosure

  • Industrial Grade Circuit Breaker

  • Heavy Duty Full Horsepower Rated By-Pass Contactor Provides Additional Protection

  • Emergency By-Pass Selector Switch (Will Select Solid State Or Across-Line)

  • Class 20 Thermal Overload

  • Ultra Heavy Duty SCR's (1600V PIV Rated)

  • Start/Stop Pushbutton (Mounted On Door)

  • Run Pilot Light (Mounted On Door)

  • Terminal Strip For Remote Connections (Mounted In Panel)

  • 115 Volt Control Power Transformer

  • ESP100 Solid State Overload Provides True Motor Phase Loss Protection (Trips Within 3 Seconds)

  • Solid State Reduced Voltage Starting Allows Motor Voltage To Be Gradually Applied, Reducing Potentially Damaging High In Rush Current and Starting Torques

  • Provides A Smooth Start, Eliminating Physical Stresses To The System and Load While Minimizing Current

  • Flexibility:

    • Single-Speed and Reversing

    • Voltage Ramp To Handle Varying Loads

  • Ramp Up / Ramp Down (Soft Start / Soft Stop)

  • UL Listed / CSA Certified

HP By Voltage

Model

Number

Operational

Current

Rating Amp

Dimensions

H X W X D"

(Inches)

230V

460V

575V

15 25 30 ACDSSRV4-25 36 36X20X11
20 40 50 ACDSSRV4-40 57 36X20X11
25 50 60 ACDSSRV4-50 69 46X20X10
-- 75 -- ACDSSRV4-75 105 46X20X10
50 100 125 ACDSSRV4-100 130 53X25X10
75 150 -- ACDSSRV4-150 192 76X22X13
100 200 250 ACDSSRV4-200 248 76X22X13
150 300 -- ACDSSRV4-300 361 90X30X20
-- 400 500 ACDSSRV4-400 480 90X30X20
-- 600 -- ACDSSRV4-600 720 90X30X20

 

 

soft starters for high-feature application

 

                                                                                 3RW4427-IBC44       3RW4436-6BC44        3RW4447-6BC44              3RW4458-6BC44                3RW4466-6BC44

Rated

Operational

Current

 

HP Rating

 

Model

Number

(use keys to complete

model numbers)

200V

230V

460V

Inline Circuits (2), Rated Operational Voltage 200...460 Volt

* Supplement Number For Connection Types

3 - With Spring-Type Terminals

1 - With Screw Terminals

■ Supplement Number For The Rated Control Supply Voltage

3 - 115 Volt AC

4 - 230 Volt AC

26

7.5

7.5

15

3RW4422- *  BC 4

32

10

10

20

3RW4423- *  BC 4

42

10

15

25

3RW4424- *   BC 4

51

15

15

30

3RW4425- *   BC 4

68

20

20

50

3RW4426- *  BC 4

82

25

25

60

3RW4427- *   BC 4

Supplement Number For Connection Types

2 - With Spring-Type Terminals

6 - With Screw Terminals

Supplement Number For The Rated Control Supply Voltage Us(1)

3 - 115 Volt AC

4 - 230 Volt AC

100

30

30

75

3RW4434-  BC 4

117

30

40

75

3RW4435-  BC 4

145

40

50

100

3RW4436-  BC 4

180

50

60

125

3RW4443-  BC 4

215

60

75

150

3RW4444-  BC 4

280

75

100

200

3RW4445-  BC 4

315

100

125

250

3RW4446-  BC 4

385

125

150

300

3RW4447-  BC 4

494 150 200 400 3RW4453-  BC 4
551 150 200 450 3RW4454-  BC 4
615 200 250 500 3RW4455-  BC 4
693 200 250 550 3RW4456-  BC 4
780 250 300 600 3RW4457-  BC 4
850 300 350 700 3RW4458-  BC 4
970 350 400 800 3RW4465-  BC 4
1076 350 400 900 3RW4466-  BC 4

Overview:

In Addition To Soft Starting and Soft Ramp-Down,

The Solid-State SIRIUS 3RW44 Soft Starters Provide

Numerous Functions For Higher-Level Requirements.

 

The SIRIUS 3RW44 Soft Starters Are Characterized

By A Compact Design For Space-Savings. For

Optimized Motor Starting and Stopping The

Innovative 3RW44 Soft Starters Are An Attractive

Alternative With Considerable Savings Potential

Compared To Applications With A Frequency

Converter. The New Torque Control and Adjustable

Current Limiting Enable The High-Feature Soft

Starters To Be Used In Nearly Every Conceivable Task.

They Guarantee The Reliable Avoidance Of Sudden

Torque Applications and Current Peaks During Motor

Starting and Stopping. This Creates Savings Potential

When Calculating The Size Of The Switchgear

and When Servicing The Machinery Installed.

 

The Bypass Contacts Already Integrated In The Soft

Starter Bypass The Thyristors After A Motor Ramp-

Up Is Detected. This Results In A Further Reduction

In The Heat Loss Occuring During Operation Of

The Soft Starter.

 

Application:

The SIRIUS 3RW44 Solid-State Soft Starters Are

Suitable For The Torque-Controlled Soft Starting

and Smooth Ramp-Down As Well As Braking

Of Three-Phase Asynchronous Motors.

 

Applications:

  Pumps  ●  Saws  ●  Fans  ●  Crushers  ●  Compressors

  ●  Hydraulics  ●  Mills  ●  Mixers

 

 

(1) Control By Way Of The Internal 24 Volt DC Supply and Direct Control By Means Of PLC Possible

 

(2) For Inside Delta Selection Contact Sales Office