Printer's Parts Store, Inc.

 

7409 NW 103 Terrace      Oklahoma City, OK  73162

 

405-721-1701     1-800-375-3787          ppsokc@aol.com  

 

ACROSS LINE STARTERS

 

 

ACROSS LINE STARTERS
Home Up DOWNLOADS NEW EQUIPMENT USED EQUIPMENT

 

 

 

 

Across-Line Motor Starters

Manual Control Starters & Switches

Heavy Duty Motor Starters With Ambient Compensated Bimetal Overload

Heavy Duty Motor Starters With ESP200 Soild State Overload

Combination Motor Starters

Irrigation Pump Panels

Overload Relay Heater Tables For Definite Purpose Starters

Replacement coils for definite purpose starters

overload relay heater tables for irrigation pump panels & heavy duty starters

replacement coils for irrigation pump panels & heavy duty starters

 

 

Across-Line Motor Starters

 

Across-Line Motor Starters

NEMA 1 Steel Enclosed Heavy Duty Starter

With ON/OFF Pushbutton. Pre-Wired,

Easy To Set Up.

 

Features:

  • 2HP 200HP

  • Multiple AC Coil 200, 230, 460 & 576 Volt

  • Adjustable Differential Thermal Overload For Better Motor Protection

  • Conduit Knockouts For Easy Wiring

  • Automatic Reset Handle

  • Screw Type Termination

  • Auxiliary Contacts

  •  3 Pole Contacts

  •  Space Saving Design

 

Application

  • Pumps

  • Fans

  • Conveyors

  • Food Processing Equipment

  • Farm Equipment Application

  • Bench Saws

  • Compressors

  • Commercial & Residential Use

  • Grinders

 

 

 

Max

HP

Voltage

Amp Range

Model

Number

 

Three-Phase

2 230 5-8 WALS2/230/5-8  
5 460 5-8 WALS5/460/5-8  
3 230 7-10 WALS3/230/7-10  
3 230 9-15 WALS3/230/9-15  
7.5 460 9-13 WALS7.5/460/9-13  
5 230 12-18 WALS5/230/12-18  
10 460 12-18 WALS10/460/12-18  
7.5 230 18-26 WALS7.5/230/18-26  
10 230 24-36 WALS10/230/24-36  
20 460 24-36 WALS20/460/24-36  
25 460 28-40 WALS25/460/28-40  
15 230 34-50 WALS15/230/34-50  
30 460 34-50 WALS30/460/34-50  
20 230 45-65 WALS20/230/45-65  
40 460 45-65 WALS40/460/45-65  
25 230 54-75 WALS25/230/54-75  
50 460 54-75 WALS50/460/54-75  
30 230 63-85 WALS30/230/63-85  
30 230 65-100 WALS30/230/65-100  
60 460 65-100 WALS60/460/65-100  
40 100-240 85-125 WALS40/100-240/85-125  
75 440-575 85-125 WALS75/440-575/85-125  
50 100-240 100-150 WALS50/100-240/100-150  
100 440-575 100-150 WALS100/440-575/100-150  
60 100-240 120-180 WALS60/100-240/120-180  
125 440-575 120-180 WALS125/440-575/120-180  
75 100-240 160-240 WALS75/100-240/160-240  
150 440-575 160-240 WALS150/440-575/160-240  
100 100-240 200-300 WALS100/100-240/200-300  
200 440-575 220-300 WALS200/440-575/220-300  

Three-Phase - With 115 Volt Coil

2-5 230/460 5-8 WALS2-5/115/5-8  
3 230 7-10 WALS3/115/7-10  
3-7.5 460 9-13 WALS3-7.5/115/9-13  
5-10 230/460 12-18 WALS5-10/115/12-18  
7.5 230 18-26 WALS7.5/115/18-26  
10-20 230/460 24-36 WALS10-20/115/24-36  
25 460 28-40 WALS25/115/28-40  
15-30 230/460 34-50 WALS15-30/115/34-50  
20-40 230/460 45-65 WALS20-40/115/45-65  
25-50 230/460 54-75 WALS25-50/115/54-75  
30 230 63-85 WALS30/115/63-85  
 

Coil Voltage Table

Nominal (Ordering) Voltage AC 50/60Hz DC
24-25V 24-25V 24
48V 48-50V 48V
100/200V 100-240V 100-200V
300V 265-347V -
400V 380-450V -
500V 440-575V -

 

 

 

Manual Control Starters & Switches

 

Open Type

 

NEMA 1

 

NEMA 7 & 9

 

NEMA 3 & 4,

NEMA 7 & 9

Class 11 - 3RV:

Class 11 Across The Line Manual Starters & Switches Provide Control For Machinery Where Remote Start Stop Control Is Not Required.

 

Class 11 - 3RV Manual Starters Are Used For Single and Poly-Phase Motors Up To 15 HP @ 460 Volt. Starters Have Bimetallic Heater Elements To Provide Class 10 Overcurrent Protection. Each Starter Has A Fourth Bimetallic Strip That Reacts Only To The Ambient Temperature Inside The Control Panel. This Ambient Compensation Helps Prevent The Starter From Nuisance Tripping When The Panel

Temperature Is Higher Than The Ambient Temperature Of The Motor.

 

A Built-In Differential Trip Bar Causes The Starter To Trip Faster On A Phase Loss Condition To Help Reduce Motor Damage.

 

Magnetic Trip Elements In Each Starter Take The Device Off Line When It Senses Current Of 13 Times The Maximum FLA Dial Setting.

 

Class 11 - 3RV Switches Provide Control For Inherently Protected Motors. Typical Applications Include Metal and Woodworking Machinery, Grinders, Power Saws, Conveyors, Fans, Pumps, Blowers, Textile and Packaging Machinery and Paper Cutters.

 

Each Switch Is Provided With Magnetic Trip Elements Which Take The Device Off Line When It Senses Current Of 13 Times The Maximum Switch Rating.

 

Class 11 - 3RV Manual Starters Can Be Used As Type E Self-Protected Manual Combination Starters (Up To 22 Amps) Per UL508 Or As Components In Group Installation Per NEC 430.53. When Using The Class 11 - 3RV As A Manual Combination Starter, Upstream Protection Is Not Required.

 

Class 11:

These Manual Controllers Are Available With Low Voltage Protection Which Will Automatically Open The Power Poles When The Voltage Drops Or The Power Is Interrupted.

 

Controllers With The LVP Option Provide The OSHA Requirement For Protecting Personnel From Potential Injury Caused By The Automatic Start-Up Of Machinery Following A Voltage Drop Or Power Interruption When Low Voltage Protection Is Specified.

 

Class 11 - 3RV Is Available As Open Style Or In NEMA 1, NEMA 7 & 9 Or NEMA 7 & 9 / NEMA 3 & 4 Enclosures.

 

Standard Features Include:

  • ON / OFF Rotary Handle With Lockout  and VisibleTrip Indication.

  • Adjustment Dial For Setting To Motor FLA (Starters Only).

  • Low Voltage Protection (LVP) Option.

  • Short Circuit Trip At 13 Times The Maximum Setting Of The FLA Dial Or Rated Current.

  • Ambient Compensated Up To 140F.

  • Phase Loss Sensitivity.

  • Test Trip Function.

  • LVP Option Meets OSHA Requirements.

  • UL Listed

  • CSA Certified

  • (1) instantaneous magnetic trip will occur at 13 times the maximum FLA dial setting or rated switch current

  • (2) these ratings apply for manual motor controls only!

  • these ratings do not apply as Ul listed manual combination starters

Ordering Information:

  • No Heaters Required.

  • For Applications Requiring Low VoltageProtection Coil See Table Below.

60 Hz Voltage

Letter

120V

*F

208V

*D

240V

*G

460V

*H

* Add corresponding letter to end of base class 11 model number for low voltage protection coil.

$210 list adder.

 

FLA Adj.

Range (1)

Max. HP Enclosure

Single-Phase

Three-Phase

Open

NEMA 1

NEMA 7 & 9

NEMA 3 & 4

NEMA 7 & 9

115V

230V

200V

230V

460V

575V

Model

Number

 

Model

Number

 

Model

Number

 

Model

Number

 
Manual Starters - Class 11 - 3RV, 3 Phase
0.11-0.16 -- -- -- -- -- -- 3RV1021-0AA10   11AD3B   11AD3H   11AD3W  
0.14-0.2 -- -- -- -- -- -- 3RV1021-0BA10   11BD3B   11BD3H   11BD3W  
0.18-0.25 -- -- -- -- -- -- 3RV1021-0CA10   11CD3B   11CD3H   11CD3W  
0.22-0.32 -- -- -- -- -- -- 3RV1021-0DA10   11DD3B   11DD3H   11DD3W  
0.28-0.4 -- -- -- -- -- -- 3RV1021-0EA10   11ED3B   11ED3H   11ED3W  
0.35-0.5 -- -- -- -- -- -- 3RV1021-0FA10   11FD3B   11FD3H   11FD3W  
0.45-0.63 -- -- -- -- -- -- 3RV1021-0GA10   11GD3B   11GD3H   11GD3W  
055-0.8 -- -- -- -- -- -- 3RV1021-0HA10   11HD3B   11HD3H   11HD3W  
0.7-1 -- -- -- -- 1/2 -- 3RV1021-0JA10   11JD3B   11JD3H   11JD3W  
0.9-1.25 -- -- -- -- 3/4 -- 3RV1021-0KA10   11KD3B   11KD3H   11KD3W  
1.1-1.6 -- 1/10 -- -- 3/4 -- 3RV1021-1AA10   11LD3B   11LD3H   11LD3W  
1.4-2 -- 1/8 -- -- 1 1 1/2 3RV1021-1BA10   11MD3B   11MD3H   11MD3W  
1.8-2.5 -- 1/6 1/2 1/2 1 1/2 1 1/2 3RV1021-1CA10   11ND3B   11ND3H   11ND3W  
2.2-3.2 1/10 1/4 3/4 3/4 1 1/2 2 3RV1021-1DA10   11PD3B   11PD3H   11PD3W  
2.8-4 1/8 1/3 3/4 1 2 3 3RV1021-1EA10   11QD3B   11QD3H   11QD3W  
3.5-5 1/6 1/2 2 1 3 3 3RV1021-1FA10   11RD3B   11RD3H   11RD3W  
4.5-6.3 1/4 3/4 1 1/2 1 1/2 5 5 3RV1021-1GA10   11SD3B   11SD3H   11SD3W  
5.5-8 1/3 1 2 2 5 5 3RV1021-1HA10   11TD3B   11TD3H   11TD3W  
7-10 1/2 1 1/2 3 3 7 1/2 10 (2) 3RV1021-1JA10   11UD3B   11UD3H   11UD3W  
9-12.5 1/2 2 3 3 7 1/2 10 3RV1021-1KA10   11VD3B   11VD3H   11VD3W  
11-16 1 3 5 5 10 15 (2) 3RV1021-4AA10   11WD3B   11WD3H   11WD3W  
14-20 1 1/2 3 5 7 1/2 15 20 (2) 3RV1021-4BA10   11XD3B   11XD3H   11XD3W  
17-22 2 3 7 1/2 7 1/2 15 20 (2) 3RV1021-4CA10   11YD3B   11YD3H   11YD3W  
20-25 2 (2) 5 (2) 7 1/2  (2) 7 1/2 (2) 15 20 (2) 3RV1021-4DA10   11ZD3B   11ZD3H   11ZD3W  

Manual Switches - Class 11 - 3RV, 3 Phase

1 -- -- -- -- 1/2 (2) 1/2 (2) 3RV1321-0JC10   111D3B   111D3H   111D3W  
5 1/6 (2) 1/2 (2) 1 (2) 1 (2) 3 (2) 3 (2) 3RV1321-1FC10   112D3B   112D3H   112D3W  
10 1/2 (2) 1 1/2 (2) 3 (2) 3 (2) 71/2 (2) 10 (2) 3RV1321-1JC10   113D3B   113D3H   113D3W  
20 1 1/2 (2) 3 (2) 5 (2) 7 1/2 (2) 15 (2) 20 (2) 3RV1321-4BC10   114D3B   114D3H   114D3W  
25 2 (2) 5 (2) 7 1/2 (2) 7 1/2 (2) 15 (2) 20 (2) 3RV1321-4DC10   115D3B   115D3H   115D3W  

 

 

Heavy Duty Motor Starters With Ambient Compensated Bimetal Overload

WSHP32A*81

Features:

  • Rugged Industrial Design

  • Half Sizes For Cost and Space Savings

  • Dual Voltage, Dual Frequency Coils

  • Ambient Compensated Bimetal Overload Protection

  • Wide Range Of Accessories

  • Easy Coil Access

  • Overload Test Feature

  • Straight Thru Wiring

  • Gravity Dropout

  • Large Silver Cadmium Contacts

  • * use coil table below to complete model number

60 Hz Voltage Letter
24 separate control J
120 separate control F
110-120/220-240 A
200-208 D
220-240 G
277 L
220-240/440-480 C
440-480 H
550-600 E

 

Application:

Heavy Duty Starters Are Designed For Across The Line

Starting Of Single Phase and Polyphase Motors.

 

These Controls Are Available In NEMA Sizes 00

Through 4. In Addition To The Usual NEMA Starter

Sizes, We Offer Three Exclusive Half Sizes; 1-3/4,

2-1/2 and 3-1/2. These Integral Sizes Offer The Same

Rugged, Industrial Construction As Our NEMA Sizes and

Ensure Efficient Operating Performance. Half Sizes

Provide A Real Cost Savings By Cutting Down On Over

Capacity When NEMA Sizes Exceed The Motor Ratings.

All Heavy Duty Controls, Including Our Popular Half

Sizes, Comply With Applicable NEMA and UL Tests.

 

All Starters Are Supplied With A NO Holding Interlock

That In Conjunction With An Appropriate Pilot Device

Will Provide Low Voltage Protection Or Release

 

Starters Are Available As An Open Type Or In NEMA 1,

12/3R, 4 (Painted), 4/4X (Stainless), 4X (Fiberglass)

and 7 & 9 Enclosures.

 

Please refer to heater tables for heater selection

     three-phase starters require 3 heater elements

     single-phase starters require 1 heater element

 

 

open type & standard width enclosure - three-phase - 3-pole

max hP

 

 

 

nEMA

size

 

 

Contactor

amp

rating

enclosure

 

 

 

200V

 

 

 

230V

 

 

 

460V

 

 

 

575V

open

NEMA 1

NEMA 12

NEMA 3/3R

NEMA 4/4X

Stainless Steel

NEMA 4X

Fiberglass

NEMA 7 & 9

NEMA 3 & 4

model

number

Model

number

model

number

List

Price

model

number

 

model

number

model

number

1 1/2

1 1/2

2

2

00

9

WSBP32A*81

WSBP32B*81 Use Size Zero Use Size Zero Use Size Zero Use Size Zero

3

3

5

5

0

18

wSCP32A*81

WSCP32B*81

WSCP320*81

  WSCP32W*81   WSCP32F*81 WSCP32H*81

7 1/2

7 1/2

10

10

1

27

wSDP32A*81

WSDP32B*81

WSDP320*81

  WSDP32W*81   WSDP32F*81 WSDP32H*81

10

10

15

15

1 3/4

40

wSEP32A*81

WSEP32B*81

WSEP320*81

  WSEP32W*81   WSEP32F*81 WSEP32H*81

10

15

25

25

2

45

wSFP32A*81

WSFP32B*81

WSFP320*81

  WSFP32W*81   WSFP32F*81 WSFP32H*81

15

20

30

30

2 1/2

60

wSGP32A*81

WSGP32B*81

WSGP320*81

  WSGP32W*81   WSGP32F*81 WSGP32H*81

25

30

50

50

3

90

wSHP32A*81

WSHP32B*81

WSHP320*81

  WSHP32W*81   WSHP32F*81 WSHP32H*81

30

40

75

75

3 1/2

115

wSIP32A*81

WSIP32B*81

WSIP320*81

  WSIP32W*81   WSIP32F*81 WSIP32H*81

40

50

100

100

4

135

wSJP32A*81

WSJP32B*81

WSJP320*81

  WSJP32W*81

 

WSJP32F*81 WSJP32H*81

 

 

open type & standard width enclosure - three-phase - 3-pole

max hP

 

 

 

nEMA

size

 

 

Contactor

amp

rating

enclosure

 

 

 

115V

 

 

208/

230V

open

NEMA 1

NEMA 12

NEMA 3/3R

NEMA 4/4X

Stainless Steel

NEMA 4X

Fiberglass

NEMA 7 & 9

NEMA 3 & 4

model

number

Model

number

model

number

model

number

model

number

model

number

1/3 1

00

9

WSBP12A*81 WSBP12B*81 Use Size Zero Use Size Zero Use Size Zero Use Size Zero
1 2

0

18

WSCP12A*81 WSCP12B*81 WSCP120*81 WSCP12W*81 WSCP12F*81 WSCP12H*81
2 3

1

27

WSDP12A*81 WSDP12B*81 WSDP120*81 WSDP12W*81 WSDP12F*81 WSDP12H*81
3 5

1P

40

WSEP12A*81 WSEP12B*81 WSEP120*81 WSEP12W*81 WSEP12F*81 WSEP12H*81
3 7 1/2

2

45

WSFP12A*81 WSFP12B*81 WSFP120*81 WSFP12W*81 WSFP12F*81 WSFP12H*81
5 10

2 1/2

60

WSGP12A*81 WSGP12B*81 WSGP120*81 WSGP12W*81 WSGP12F*81 WSGP12H*81

 

Heavy Duty Motor Starters With ESP200 Soild State Overload

 

WSCUD32A

ESP200 Starters Combine The Rugged

NEMA Contactors With A State Of The Art

Solid State Overload That Provides Phase Loss,

And Phase Unbalance Ground Fault Protection.

It Offers The User Greater Motor Protection and

Extended Life In Heavy Duty Applications. The

Inherent Benefits Of The ESP200 Result In

Cost Savings As Well.

 

Coil Table

60 Hz Voltage Letter
24 seperate control J
120 seperate control F
110-120/220-240 A
200-208 D
220-240 G
277 L
220-240/440-480 C
440-480 H
550-600 E

 

Options
Hand-Off-Auto Switch
Pilot Light
Start/Stop Pushbutton

ESP200 Solid State Overload Relays:

Standard Features Of The ESP200

Provide Improved Starter Performance.

  • True Phase Loss Protection - Trips Within 3 Seconds

  • Phase Unbalanced Prevents Motor Running Inefficiently

  • Ground Fault Trip When Selected

  • Selectable Trip Class - 5, 10, 20 or 30

  • Reset Trip Can Be Selected Auto / Manual Reset

  • Overload Is Self Powered, No Need For External Power Source

  • Easy To Select and Use, DIP Switch Selectable

  • Rugged Industrial Design

  • Half Sizes For Cost and Space Savings

  • Dual Voltage, Dual Frequency Coils

  • Wide Range Of Accessories

  • Easy Coil Access

  • Overload Test Feature

  • Straight Thru Wiring

  • Gravity Dropout

  • Large Silver Cadmium Contacts

  • UL Listed and CSA Certified

  • *  use coil table at the left to complete model number

  • models WSLPU32E - WSPUN32E Have Steel Painted Enclosures

please refer to the coil tables for replacement coils

 

 

 

max hP

 

 

 

nEMA

size

 

 

Overload

Amp

Range

enclosure

 

 

 

200V

 

 

 

230V

 

 

 

460V

 

 

 

575V

open

NEMA 1

NEMA 12

NEMA 3/3R

NEMA 4/4X

Stainless Steel

NEMA 4X

Fiberglass

NEMA 7 & 9

NEMA 3 & 4

model

number

 

Model

number

 

model

number

 

model

number

 

model

number

 

model

number

 
1/6 1/6 1/3 1/2 00 0.25-1 WSBUA32A*   WSBUA32B*   Use Size Zero Use Size Zero Use Size Zero Use Size Zero
1/2 3/4 1 1/2 2 00 0.75-3.4 WSBUB32A*   WSBUB32B*   Use Size Zero Use Size Zero Use Size Zero Use Size Zero
1 1/2 1 1/2 2 -- 00 3-12 WSBUC32A*   WSBUC32B*   Use Size Zero Use Size Zero Use Size Zero Use Size Zero
1/6 1/6 1/3 1/2 0 0.25-1 WSCUA32A*   WSCUA32B*   WSCUA320*   WSCUA32W*   WSCUA32F*   WSCUA32H*  
1/2 3/4 1 1/2 2 0 0.75-3.4 WSCUB32A*   WSCUB32B*   WSCUB320*   WSCUB32W*   WSCUB32F*   WSCUB32H*  
2 2 5 5 0 3-12 WSCUC32A*   WSCUC32B*   WSCUC320*   WSCUC32W*   WSCUC32F*   WSCUC32H*  
3 3 -- -- 0 5.5-22 WSCUD32A*   WSCUD32B*   WSCUD320*   WSCUD32W*   WSCUD32F*   WSCUD32H*  
1/6 1/6 1/3 1/2 1 0.25-1 WSDUA32A*   WSDUA32B*   WSDUA320*   WSDUA32W*   WSDUA32F*   WSDUA32H*  
1/2 3/4 1 1/2 2 1 0.75-3.4 WSDUB32A*   WSDUB32B*   WSDUB320*   WSDUB32W*   WSDUB32F*   WSDUB32H*  
2 2 5 5 1 3-12 WSDUC32A*   WSDUC32B*   WSDUC320*   WSDUC32W*   WSDUC32F*   WSDUC32H*  
3 3 10 10 1 5.5-22 WSDUD32A*   WSDUD32B*   WSDUD320*   WSDUD32W*   WSDUD32F*   WSDUD32H*  
7.5 7.5 -- -- 1 10-40 WSDUE32A*   WSDUE32B*   WSDUE320*   WSDUE32W*   WSDUE32F*   WSDUE32H*  
10 10 15 15 1 3/4 10-40 WSEUE32A*   WSEUE32B*   WSEUE320*   WSEUE32W*   WSEUE32F*   WSEUE32H*  
10 15 25 25 2 13-52 WSFUF32A*   WSFUF32B*   WSFUF320*   WSFUF32W*   WSFUF32F*   WSFUF32H*  
15 20 30 30 2 1/2 25-100 WSGUG32A*   WSGUG32B*   WSGUG320*   WSGUG32W*   WSGUG32F*   WSGUG32H*  
25 30 50 50 3 25-100 WSHUG32A*   WSHUG32B*   WSHUG320*   WSHUG32W*   WSHUG32F*   WSHUG32H*  
30 40 75 75 3 1/2 50-200 WSIUH32A*   WSIUH32B*   WSIUH320*   WSIUH32W*   WSIUH32F*   WSIUH32H*  
40 50 100 100 4 50-200 WSJUH32A*   WSJUH32B*   WSJUH320*   WSJUH32W*   WSJUH32F*   WSJUH32H*  
75 100 200 200 5 55-250 WSLPU32A*   WSLPU32B*   WSLPU320*   WSLPU32W*   -- -- WSLPU32H*  
150 200 400 400 6 160-630 WSMPX32A*   WSMPX32B*   WSMPX320*   WSMPX32W*   -- -- -- --
-- 300 600 600 7 400-1220 WSNUN32A*   WSNUN32B*   WSNUN320*   WSNUN32W*   -- -- -- --
-- 450 900 900 8 400-1220 WSPUN32A*   WSPUN32B*   WSPUN320*   WSPUN32W*   -- -- -- --

 

Combination Motor Starters

 

Features:

Combination Starters Include The Following Features:

  • Manufactured With Cold Forming "Tox" Process.

  • Solid State Overloads Standard On Sizes 5 - 8.

  • Easy To Install.

  • Wide Range Of Enclosure Types Available.

  • Heavy Duty Quarter Turns.

  • 100 kA Short Circuit Current Rating When Protected With Class R Fuses To 600V Or MCD To 480V.

  • Visible Blade Disconnect

  • Industrial Type Disconnect Handle

 

Application:

A Combination Starter Meets National Code Requirements For:

  • A Means Of Providing Short Circuit Motor Protection With Fused Or Breaker Disconnection Of Line Voltage.

  • A Means Of Safeguarding Personnel From Contact With Live Parts and From Accidental Starting Of Machinery By Disconnecting The Motor and The Controller.

  • A Motor Controller With Overload Protection.

Prewired Combination Starters Eliminate The Cost of Wiring Between Separate Disconnect and Starter. Factory Testing Assures Field Performance. Combination Starters Also Provide A More Compact and Attractive Installation Than Separate Units.

 

Enclosure Types:

Combination Starters Are Available In NEMA 1, 12/3/3R/4 (Painted), 4/4X T (Stainless), 4X Fiberglass and 7 & 9 Enclosures. Enclosures Protect Personnel From Contact With Live Parts and Depending Upon The Construction, Protect The Control In Varying Degrees From Physical Damage and Harmful Atmospheres. All Enclosures Are Supplied With Corrosion Resistant Finishes.

 

New Heavy Duty Disconnect Switches:

The Disconnect Switch That Goes The Distance In Durability, Performance and Reliability Has Been Made Even Better To Give You Greater Advantages:

  • Visible Blade For The Highest Level Of Safety.

  • Double Break Switching Action To Reduce Arcing, Increase Lifetime and Eliminate The "Electric Hinge".

  • More Rugged Positive Action Switch.

  • Oversized Lugs Are Standard.

  • Line Side Shield To Help Guard Personnel From Contact With Live Parts.

  • Higher Horsepower Rating For Design E High Efficiency Motors.

  • Now UL Listed For Ilsco, Burndy and T & B Crimp Type Lugs.

It's Rugged Construction - With A High Fault Withstand Rating Of 100 kA At 600 VAC When Fused With Class R Rated Fuses - Meets The Most Stringent Industry Standards Set Forth By The  Automotive, Petro-Chemical and Pulp and Paper Industries. UL Recognized and CSA Certified, Our Disconnect Switches Are Available Either Non-Fusible Or Fusible With Class R and Class J Fuse Clips.

 

Type ETI Circuit Breaker:

The ETI Circuit Breaker Is A Device Designed Specifically For Application In Motor Circuits. The ETI Is A Magnetic Only Protective Device Designed To Provide Against Short Circuit Current.

 

The Instantaneous-Only Type ETI Circuit Breaker Employs Adjustable Magnetic Trip Settings To Allow Broader Application Ranges and A Higher Degree Of Motor Short Circuit Protection.

 

Heavy Duty Starters:

These Combination Starters Use The Same Starters Described In The Heavy Duty Starter Section Of This Catalog. ESP100

Solid State Overload Starters and Ambient Compensated Bimetal Overload Starters Are Available

 

 

Call For
Pricing

 

Irrigation Pump Panels

Features

Specified By Fortune 500 Companies, ESP100 Or Thermal Starters Offer Prolonged Service Under Severe Duty Conditions. NEMA Rated, These Starters Utilize Large Silver Cadmium Oxide Contacts and Wide Copper Heat Sinks To Ensure Rapid Heat Dissipation and Maximum Electrical Life.

  • ESP100 Solid State Overload Relays Provide Phase Loss Protection For The Motor By Tripping Within Three Seconds Upon Complete Loss Of One Phase In A Three Phase Circuit. Each Overload Has A 2:1 (4:1 In Lower Ranges) FLA Adjustment Range With An Adjustment Dial Reading Out In FLA. This Feature Allows For Extreme Fine Tuning. Their Heaterless Construction Minimizes Energy Costs and Costs of Cabinet Ventilation Or Cooling.

  • The Ambient Compensated Bimetal Overload Relays Are Designed To Parallel Thermal Characteristics Of Typical Pump Motors. They Prevent

  • Nuisance Trips That May Result From Operation Of The Control In A Higher Ambient Temperature Than The Pump. These Relays Are Trip-Free, Tamperproof and Can Be Set To Reset Automatically Or Manually.

  • HOA and Start Pushbutton Every Pump Panel Comes With An HOA and A Start Pushbutton.

  • Half Size Starters - Motor Matched Starters Feature All Rugged Performance Characteristics Of Our NEMA Rated Starter Sizes, But Are Fractionally Sized To More Closely Match Your Exact Motor Rating. As A Result, Significant Economic Savings Are Made Possible Without Sacrificing The Reliability You Expect From A Heavy Duty Starter. These Additional Starter Sizes Have The Reserve Capacity To Handle Occasional Plugging and Jogging Without De-Rating The Device. Motor Matched Starters Can Save Hundreds, Even Thousands Of Dollars Per Project. Motor Matched Starters Comply With NEMA, UL and CSA Standards.

Application:

  • Heavy Duty Irrigation Pump Panels Are Designed To Withstand The Most Demanding Environments. Typical Applications Include Irrigation, Agriculture, Petrochemical, Wastewater Treatment and Wherever The Motor Control Is Challenged By Harsh Elements.

  • Class 87 Irrigation Pump Panels Become Jockey Pump Panels With The Addition Of A Pressure Switch. The Jockey Pump's Primary Function Is To Maintain Water Pressure At A Preset Level and Thus Compensate For Possible Shortage Of Water In The Pumping System. When The Water Pressure Drops Below The Present Level, The Pressure Switch Energizes The The Starter Which In Turn Activates The Jockey Pump. The Water Pressure Is Then Brought Back Up To The Desired Level. This Insures The Maintenance Of Proper Water Pressure At All Times.

  • Rugged Pump Panels Utilize The Cold Maintenance Work Can Be Performed Forming "Tox Process". They are More Rainproof, Sleet and Ice Resistant Than In The Past.

  • Installation Is Easy. Panels Are Factory Wired To Provide Flexible Control and Protect Against Short Circuits and Overloads. Ample Space Is Provided For Field Modifications and Installation Of Accessories.

  • The Irrigation Pump Panels Feature A Full Sized, Removable Auxiliary Panel For The Mounting Of Accessories. The FusibleVersion Features Fuse Clips For Full Sized RK5 Or Compact Class J Fuses and Accessory Mounting Space For The Most Commonly Used Accessories.

 

Benefits:

Panels Are Predrilled For Easy Repositioning Of The Fuse Trailer Block To Accommodate 250 and 600 Volt Fuses and Full Sized RK Or Compact J Fuses. Circuit Breakers Are Also Available.

  • Heavy Duty Fusible Disconnect Switch Has Been Made Even Better To Give You Greater Advantages:

    • Visible Blades For The Highest Level Of Safety.

    • Double Break Switching Action To Reduce Arcing, Increase Lifetime and Eliminate The "Electric Hinge".

    • Oversized Lugs Are Standard.

    • Line Side Shield To Help Guard Personnel From Contact With Live Parts.

  • Motor Circuit Protector Provides Fast, Accurate Fault Clearing That Will Minimize Damage To The Motor and Control Apparatus and Protect Branch Circuit Conductors. Continuous Current Ratings and Adjustable Trip Ranges Meet NEC Requirements For Full Load and Locked Rotor Currents. The Adjustable Instantaneous Trip Point Can Be Set Precisely To Assure Fault Protection and Eliminate Nuissance Tripping.

  • Removable Door May Be Lifted Off To Make Wiring Easier.

  • Mounting Flanges At Top and Bottom Of The Enclosure Provide Easy Mounting. They Fit Pole Or Flat Surfaces Using Keyhole Slots.

  • Quarter Turn Latches Are Utilized To Secure The Door.

  • Wind Catches Are Provided To Prevent The Door From Slamming Shut (Or Open) Due To High Wind Conditions.

  • Safety Disconnect Handle - Up To Three Padlocks Can Be Used To Lock The Disconnect In The OFF Position. Maintenance Work Can Be Performed Without Hazard To Personnel.

  • External Reset - The Overload Relay May Be Quickly Reset By Means Of A Button On The Front Of The Enclosure.

  • Bold Pilot Legend Provides Positive Indication Of The Selector Switch Position For Use To Stop The Pump Motor.

  • Ground Lugs Insure Proper Connecting Of Ground Wires And Lightning Arrestors.

  • UL Listed - Assures Proper Construction Throughout The Control Panel.

Auxiliary Equipment:

  • Pilot Lights Are Easily Installed On The Enclosure. Oil Tight and Heavy Duty, They Meet NEMA A600 Requirements.

  • Lightning Arresters Protect The Control Panel From Lightning Induced Surges.

  • Undervoltage and Phase Sensing Relays Protect The Pump Against Low Voltage, Voltage Imbalance, Loss Of Phase and Phase Reversal.

  • Anti-Backspin Timers Prevent The Motor From Starting During Motor / Shaft Backspin.

  • Pressure Switches Provide Easy Installation, Inspection and Adjustment With The 69ES Pro Control Pressure Switch.

  • GARD-IT, For Low Water Condition Protection.

  • HI-GARD, Used In Conjunction With A Standard Pressure Switch To Protect Against Undesirable Pressure Rises in Your System.

  • The TOX Process Is Used To Manufacture The Enclosures For The Pump Panels.

  • Advantages Of The TOX Process:

    • Joints Are 50-70% Stronger.

    • Since The TOX Process Compresses The Metal At The Joint, It Does Not Leave The High Stresses In The Metal.

    • Increased Corrosion Resistance. The Protective Layer On The Metal Is Not Damaged In The Process, But Instead Flows With The Material

     

 
  • Fully Gasketed NEMA 3R Rainproof Enclosures

  • 100,000 Amp Interrupting Capacity With Class R Fuses

  • Heavy Duty NEMA Starters

  • Solid State Or Ambient Compensated Bi-Metal Overload Relays

  • Heavy Duty Disconnect Handle

  • Bold Pilot Legend On Front

  • Generous Accessory Space

  • Copper Grounding Lug For Three #6 Wires

  • UL Listed For Outdoor Use and Service Equipment File #E14900

  • CSA Certified File #LR6535

Use Heater Tables For Heater Selection

 

Use Coil Tables For Replacement Coils

 

Max HP

 

 

Size

Solid State Overload

Ambient Compensated Overload

 

200V

 

230V

 

460V

 

575V

 

O/L Amp

Range

Fuse/

Breaker

Size

 

Model

Number

 

Fuse/

Breaker

Size

 

Model

Number

 

Fusible Disconnect

 

 

10

10

1

9-18

30

IPP1-460-ESP

 

30

IPP1-460

 

7.5

7.5

 

 

1

13-27

30

IPP1-230-ESP

 

30

IPP1-230

 

 

 

15

15

1.75

13-27

30

IPP1.75-460-ESP

 

30

IPP1.75-460

 

10

10

 

 

1.75

20-40

60

IPP1.75-230-ESP

 

60

IPP1.75-230

 

 

 

25

25

2

22-45

60

IPP2-460-ESP

 

60

IPP2-460

 

10

15

 

 

2

22-45

60

IPP2-230-ESP

 

60

IPP2-230

 

 

 

30

30

2.5

22-45

60

IPP2.5-460-ESP

 

60

IPP2.5-460

 

15

20

 

 

2.5

30-60

60

IPP2.5-230-ESP

 

100

IPP2.5-230

 

 

 

50

50

3

45-90

100

IPP3-460-ESP

 

100

IPP3-460

 

25

30

 

 

3

45-90

100

IPP3-230-ESP

 

100

IPP3-230

 

 

 

75

75

3.5

57-115

200

IPP3.5-460-ESP

 

200

IPP3.5-460

 

30

40

 

 

3.5

57-115

200

IPP3.5-230-ESP

 

200

IPP3.5-230

 

 

 

100

100

4

67-135

200

IPP4-460-ESP

 

200

IPP4-460

 

40

40

 

 

4

67-135

200

IPP4-230-ESP

 

200

IPP4-230

 

 

 

200

200

5

100-270

400

IPP5-460-ESP

 

 

 

 

75

100

 

 

5

100-270

400

IPP5-230-ESP

 

 

 

 

 

 

250

 

6

200-540

600

IPP6-460-ESP

 

 

 

 

Circuit Breaker

 

 

10

10

1

9-18

30

IPPCB1-460-ESP

 

30

IPPCB1-460

 

7.5

7.5

 

 

1

13-27

30

IPPCB1-230-ESP

 

30

IPPCB1-230

 

 

 

15

15

1.75

13-27

30

IPPCB1.75-460-ESP

 

30

IPPCB1.75-460

 

10

10

 

 

1.75

20-40

50

IPPCB1.75-230-ESP

 

50

IPPCB1.75-230

 
10 15 25 25 2 22-45 50 IPPCB2-230/460-ESP   50 IPPCB2-230/460  
    30 30 2.5 22-45 50 IPPCB2.5-460-ESP   50 IPPCB2.5-460  
15 20     2.5 30-60 100 IPPCB2.5-230-ESP   100 IPPCB2.5-230  
25 30 50 50 3 45-90 100 IPPCB3-230/460-ESP   100 IPPCB3-230/460  
30 40 75 75 3.5 57-115 125 IPPCB3.5-230/460-ESP   125 IPPCB3.5-230/460  
40 50 100 100 4 67-135 150 IPPCB4-230/460-ESP   150 IPPCB4-230/460  
75 100 200 200 5 55-250 400 IPPCB5-460-ESP      

 

    250 300 6 160-540 400 IPPCB6-460-ESP        
100 125     6 160-540 400 IPPCB6-230-ESP        

 

Overload Relay Heater Tables For Definite Purpose Starters

Single-Phase

Full Load Amps

Model

Number

 

Size

25, 30, 40

Size

50, 60

-- -- E3  
-- -- E4  
-- -- E5  
-- -- E6  
0.67 -- E7  
0.73 -- E8  
0.81 -- E9  
0.88 -- E11  
0.96 -- E12  
1.05 -- E13  
1.11 -- E14  
1.20 -- E16  
1.33 -- E17  
1.43 -- E18  
-- -- E19  
1.54 -- E23  
1.81 -- E24  
2.07 -- E26  
2.30 -- E27  
2.59 -- E28  
2.86 -- E29  
3.02 -- E31  
3.29 -- E32  
3.48 -- E33  
3.81 -- E34  
4.25 -- E36  
4.51 -- E37  
4.85 -- E38  
5.27 -- E39  
5.72 -- E41  
6.40 -- E42  
7.15 -- E44  
7.78 -- E46  
8.56 -- E47  
9.43 -- E48  
9.93 -- E49  
10.3 -- E50  
11.4 -- E51  
12.6 -- E52  
13.8 -- E53  
15.2 -- E54  
16.4 -- E55  
17.6 -- E56  
19.1 -- E57  
21.7 -- E60  
25.0 25.4 E61  
28.5 29.0 E62  
30.0 30.6 E65  
33.6 34.3 E66  
39.0 39.9 E67  
45.0 46.1 E69  
47.6 48.8 E70  
55.0 56.4 E72  
-- 58.0 E73  
-- 64.0 E74  
-- 69.0 E76  
-- 81.0 E77  
-- -- E78  
-- -- E79  
-- -- E80  
-- -- E81  
-- -- E94  
-- -- E96  
-- -- E97  

Three-Phase

Full Load Amps

Model

Number

 

Size

25, 30, 40

Size

50, 60

Size

75, 90

0.36 -- -- E3  
0.40 -- -- E4  
0.44 -- -- E5  
0.47 -- -- E6  
0.51 -- -- E7  
0.55 -- -- E8  
0.61 -- -- E9  
0.67 -- -- E11  
0.72 -- -- E12  
0.78 -- -- E13  
0.83 -- -- E14  
0.91 -- -- E16  
1.01 -- -- E17  
1.07 -- -- E18  
1.16 -- -- E19  
1.25 -- -- E23  
1.36 -- -- E24  
1.55 -- -- E26  
1.72 -- -- E27  
1.93 -- -- E28  
2.12 -- -- E29  
2.26 -- -- E31  
2.43 -- -- E32  
2.60 -- -- E33  
2.83 -- -- E34  
3.18 -- -- E36  
3.37 -- -- E37  
3.61 -- -- E38  
3.93 -- -- E39  
4.26 -- -- E41  
4.77 -- -- E42  
5.32 -- -- E44  
5.78 -- -- E46  
6.37 -- -- E47  
7.02 -- -- E48  
7.40 -- -- E49  
7.70 -- -- E50  
8.38 -- -- E51  
9.43 -- -- E52  
10.3 -- -- E53  
11.2 -- -- E54  
12.3 -- -- E55  
13.0 -- -- E56  
15.1 -- -- E57  
17.1 -- -- E60  
19.6 -- -- E61  
21.4 22.5 -- E62  
23.10 25.4 -- E65  
24.8 27.1 -- E66  
27.4 29.0 -- E67  
30.6 32.0 -- E69  
32.5 34.0 -- E70  
36.8 38.0 48.4 E72  
39.5 42.0 50.0 E73  
50 49.0 55.0 E74  
55.0 54.0 59.5 E76  
-- 57.5 68.0 E77  
-- 65.0 72.5 E78  
-- -- 77.0 E79  
-- 73.0 87.0 E80  
-- 82.0 -- E81  
-- -- 95.0 E94  
-- -- 103.0 E96  
-- -- 115.0 E97  

 

 

Replacement coils for definite purpose starters

Third Character

Of Model Number

Fourth Character

Of Model Number

Volts

Model

Number

 

60Hz

50Hz

AC Coils - Class 16 and 41

 

 

 

N

 

 

 

B

24

24

75D54760J

 

110-120

110

75D54760F

 

200-208

--

75D54760D

 

208-240

208-220

75D54760G

 

277

240

75D54760L

 

440-480

380-440

75D54760H

 

550-600

550

75D54760E

 

AC Coils - Class 16, 24, 42 and 44

 

 

 

A, B, C, D, E

 

 

 

F

24

24

75D70233J / 75D70646J

 

110-120

110

75D70233F / 75D70646F

 

200-208

--

75D70233D / 75D70646D

 

208-240

208-220

75D70233G / 75D70646G

 

277

240

75D70233L / 75D70646L

 

440-480

380-440

75D70233H / 75D70646H

 

550-600

550

75D70233E / 75D70646E

 

 

 

 

F, G

 

 

 

E

24

24

75D54772J

 

110-120

110

75D54772F

 

200-208

--

75D54772D

 

208-240

208-220

75D54772G

 

277

240

75D54772L

 

440-480

380-440

75D54772H

 

550-600

550

75D54772E

 

 

 

 

 

H, I

 

 

 

 

F

24

24

75D73251J

 

110-120

110

75D73251F

 

110-120 / 220-240

110 / 190-120

75D73251A

 

200-208

--

75D73251D

 

208-240

190-220

75D73251G

 

277

240

75D73251L

 

220-240 / 440-480

190-220 / 380-440

75D73251C

 

440-480

380-440

75D73251H

 

550-600

550

75D73251E

 

 

overload relay heater tables for

irrigation pump panels & heavy duty starters

Bi-Metal Standard Tip

Full Load Amps

 

Model

Number

 

Size

00, 0, 1

Size

1 3/4

Size

2, 2 1/2

Size

3, 3 1/2

Size

4

0.38-0.40

--

--

--

--

E6

 

0.41-0.43

--

--

--

--

E7

 

0.44-0.48

--

--

--

--

E8

 

0.49-0.53

--

--

--

--

E9

 

0.54-0.57

--

--

--

--

E11

 

0.58-0.62

--

--

--

--

E12

 

0.63-0.66

--

--

--

--

E13

 

0.67-0.72

--

--

--

--

E14

 

0.73-0.80

--

--

--

--

E16

 

0.81-0.85

--

--

--

--

E17

 

0.86-0.92

--

--

--

--

E18

 

0.93-0.99

--

--

--

--

E19

 

1.00-1.08

--

--

--

--

E23

 

1.09-1.23

--

--

--

--

E24

 

1.24-1.37

--

--

--

--

E26

 

1.38-1.54

--

--

--

--

E27

 

1.55-1.69

--

--

--

--

E28

 

1.70-1.80

--

--

--

--

E29

 

1.81-1.94

--

--

--

--

E31

 

1.95-2.07

--

--

--

--

E32

 

2.08-2.26

--

--

--

--

E33

 

2.27-2.54

2.27-2.54

--

--

--

E34

 

2.55-2.69

2.55-2.69

--

--

--

E36

 

2.70-2.88

2.70-2.88

--

--

--

E37

 

2.89-3.14

2.89-3.14

--

--

--

E38

 

3.15-3.40

3.15-3.41

--

--

--

E39

 

3.41-3.81

3.41-3.81

--

--

--

E41

 

3.82-4.26

3.82-4.25

--

--

--

E42

 

4.27-4.62

4.26-4.62

--

--

--

E44

 

4.63-5.09

4.63-5.09

--

--

--

E46

 

5.10-5.61

5.10-5.61

--

--

--

E47

 

5.62-5.91

5.62-5.91

--

--

--

E48

 

5.92-6.15

5.92-6.15

--

--

--

E49

 

6.16-6.70

6.16-6.70

--

--

--

E50

 

6.71-7.54

6.71-7.54

--

--

--

E51

 

7.55-8.29

7.55-8.29

--

--

--

E52

 

8.30-8.99

8.30-8.99

--

--

--

E53

 

9.00-9.85

9.00-9.85

--

--

--

E54

 

9.86-10.4

9.86-10.4

--

--

--

E55

 

10.5-12.0

10.5-12.0

10.5-12.0

--

--

E56

 

12.1-13.6

12.1-13.6

12.1-13.6

--

--

E57

 

13.7-15.6

13.7-15.6

13.7-15.6

--

--

E60

 

15.7-17.0

15.7-17.0

15.7-17.1

--

--

E61

 

17.1-18.4

17.1-19.4

17.2-19.4

--

--

E62

 

18.5-19.4

19.5-20.9

19.5-20.9

--

--

E65

 

19.5-21.3

21.0-2.2

21.0-2.2

--

--

E66

 

21.4-24.4

22.3-25.3

22.3-25.3

--

--

E67

 

24.5-25.9

25.4-26.9

25.4-26.9

30.0-33.5

--

E69

 

26.0-27.0

27.0-30.2

27.0-30.2

33.6-36.4

--

E70

 

--

--

--

36.5-39.6

--

E71

 

--

30.3-33.3

30.3-33.3

--

--

E72

 

--

33.4-36-0

33.4-35.3

39.7-43.6

--

E73

 

--

--

--

43.7-46.5

--

E73A

 

--

--

35.4-41.5

46.6-51.6

--

E74

 

--

--

41.6-45.0

51.7-54.4

--

E76

 

--

--

45.1-52.3

54.5-58.0

--

E77

 

--

--

52.4-55.7

58.1-63.0

--

E78

 

--

--

55.8-60.0

63.1-67.7

--

E79

 

--

--

--

67.8-72.4

--

E80

 

--

--

--

--

--

E88

 

--

--

--

--

56.9-60.9

E89

 

--

--

--

--

61.0-63.9

E91

 

--

--

--

--

64.0-67.7

E92

 

--

--

--

--

67.8-72.4

E93

 

--

--

--

72.5-80.0

72.5-77.7

E94

 

--

--

--

80.1-88.1

77.8-85.9

E96

 

--

--

--

88.2-91.5

86.0-91.9

E97

 

--

--

--

91.6-96.8

92.0-96.7

E98

 

--

--

--

96.9-99.0

96.8-105

E99

 

--

--

--

99.1-108.0

--

E101

 

--

--

--

--

--

E102

 

--

--

--

--

106-115

E103

 

--

--

--

--

116-130

E104

 

Bi-Metal Quick Trip

Full Load Amps

 

Model

Number

 

Size

00, 0, 1

Size

1 3/4

Size

2, 2 1/2

Size

3, 3 1/2

Size

4

1.52-1.65

1.52-1.65

--

--

--

K21

 

1.66-1.79

1.66-1.79

--

--

--

K22

 

1.80-1.94

1.80-1.94

--

--

--

K23

 

1.95-2.15

1.95-2.15

--

--

--

K24

 

2.16-2.37

2.16-2.37

--

--

--

K26

 

2.38-2.56

2.38-2.56

--

--

--

K27

 

2.57-2.87

2.57-2.87

--

--

--

K28

 

2.88-3.13

2.88-3.13

--

--

--

K29

 

3.14-3.37

3.14-3.37

--

--

--

K31

 

3.38-3.72

3.38-3.72

--

--

--

K32

 

3.73-4.00

3.73-4.00

--

--

--

K33

 

4.01-4.35

4.01-4.35

--

--

--

K34

 

4.36-4.99

4.36-4.99

--

--

--

K36

 

5.00-5.38

5.00-5.38

--

--

--

K37

 

5.39-5.79

5.39-5.79

--

--

--

K39

 

5.80-6.43

5.80-6.43

--

--

--

K41

 

6.44-6.83

6.44-6.83

--

--

--

K42

 

6.84-7.83

6.84-7.83

--

--

--

K43

 

7.84-8.23

7.84-8.23

--

--

--

K49

 

8.24-9.59

8.24-9.59

--

--

--

K50

 

9.60-9.90

9.60-9.90

--

--

--

K52

 

10.0-10.7

10.0-10.7

--

--

--

K53

 

10.8-11.6

10.8-11.6

12.1-12.7

--

--

K54

 

11.7-12.3

11.7-12.3

12.8-13.5

--

--

K55

 

12.4-13.4

12.4-13.4

13.6-14.6

--

--

K56

 

13.5-14.2

13.5-14.2

14.7-15.9

--

--

K57

 

14.3-15.1

14.3-15.1

16.0-16.9

--

--

K58

 

15.2-17.5

15.2-17.5

17.0-18.2

--

--

K60

 

17.6-18.7

17.6-18.7

18.3-19.5

--

--

K61

 

18.8-20.0

18.8-20.0

19.6-20.9

--

--

K62

 

20.1-21.5

20.1-21.5

21.0-23.1

--

--

K63

 

21.6-23.9

21.6-23.9

23.2-25.4

--

--

K64

 

24.0-25.8

24.0-25.8

25.5-27.9

--

--

K67

 

--

25.9-29.5

--

--

--

K68

 

--

--

28.0-30.5

--

--

K69

 

--

29.6-32.7

30.6-33.5

36.8-40.0

--

K70

 

--

32.8-36.0

33.6-37.2

40.1-42.4

--

K72

 

--

--

37.3-40.7

42.5-46.3

--

K73

 

--

--

40.8-43.0

46.4-49.6

--

K74

 

--

--

43.1-47.9

49.7-52.3

49.7-52.3

K75

 

--

--

48.0-52.7

52.4-57.5

52.4-57.5

K76

 

--

--

52.8-58.3

57.6-63.9

57.6-63.0

K77

 

--

--

58.4-60.0

64.0-67.9

63.1-68.1

K78

 

--

--

--

68.0-74.3

68.2-74.3

K83

 

--

--

--

74.4-77.9

74.4-79.9

K85

 

--

--

--

78.0-83.1

80.0-87.4

K86

 

--

--

--

83.2-91.4

87.5-90.0

K87

 

--

--

--

91.5-99.9

90.1-100

K88

 

--

--

--

100-108

100.1-108

K89

 

--

--

--

--

108.1-119

K90

 

--

--

--

--

119.1-130

K92

 

--

--

--

--

--

K94

 

--

--

--

--

--

K96

 

Heaters Provide A Maximum Trip Rating Of 125% Of Minimum Motor

Amperes For 40C Motors (Service Factor 1.15). For Other Motors (Service

Factor 1.0), Select The Next Lower Listed Heater Catalog Number Within The

Designated Table Which Provides A Maximum Trip Rating Of

Approxumately 115%.

 

 

 

Overload Relays Do Not Provide Protection Against Short Circuits. To Ensure Proper Coordination With Short Circuit Protective Device, Select Heaters From The Information Packaged With The Control Device.

 

 

 

replacement coils for irrigation pump panels & heavy duty starters

 

Size

Volts

Model

Number

List

Price

60Hz

50Hz

AC Coils

00

-

2 1/2

24 24 75D73070J  
120 110 75D73070F  
110-120 / 220-240 110 / 190-200 75D73070A  
208 -- 75D73070D  
220-240 190-220 75D73070G  
277 240 75D73070L  
220-240 / 440-480 190-220 / 380-440 75D73070C  
440-480 380-440 75D73070H  
575-600 550 75D73070E  

3,

3 1/2

24 24 75D73251J  
120 110 75D73251F  
110-120 / 220-240 110 / 190-200 75D73251A  
208 -- 75D73251D  
220-240 190-220 75D73251G  
277 240 75D73251L  
220-240 / 440-480 190-220 / 380-440 75D73251C  
440-480 380-440 75D73251H  
575-600 550 75D73251E  
 

4

24 24 75D70131J  
120 110 75D70131F  
110-120 / 220-240 110 / 190-200 75D70131A  
208 -- 75D70131D  
220-240 190-220 75D70131G  
277 240 75D70131L  
220-240 / 440-480 190-220 / 380-440 75D70131C  
440-480 380-440 75D70131H  
575-600 550 75D70131E  
 

5

23-26 23-26 3RT1965-5AB31  
110-127 110-127 3RT1965-5AF31  
200-220 200-220 3RT1965-5AM31  
220-240 220-240 3RT1965-5AP31  
240-277 240-277 3RT1965-5AU31  
380-420 380-420 3RT1965-5AV31  
440-480 440-480 3RT1965-5AR31  
575-600 575-600 3RT1965-5AT31  

6

23-26 23-26 3RT1975-5AB31  
110-127 110-127 3RT1975-5AF31  
200-220 200-220 3RT1975-5AM31  
220-240 220-240 3RT1975-5AP31  
240-277 240-277 3RT1975-5AU31  
380-420 380-420 3RT1975-5AV31  
440-480 440-480 3RT1975-5AR31  
575-600 575-600 3RT1975-5AT31